SuperHot™ Complete - 15 GL drum

All-in-One Boiler Treatment
Item #121346

SuperHot™ Complete - 15 GL drum

All-in-One Boiler Treatment
Item #121346

Need Assistance? Call us 1-800-321-8180

  • Unique, high temperature, non-consumable, film-forming corrosion inhibitor
  • Excellent corrosion protection, regardless of oxygen level entering the boiler
  • Also protects boiler during late fall and early spring when boilers are off-line for long periods

Product Description

Oxygen pitting is one of the most devastating actions that can occur in steam boilers. Once corrosion starts to occur, it is difficult to stop and will eventually result in failure. The result is costly downtime, and even costlier repair.

Traditionally, oxygen pitting is controlled using an oxygen scavenger, such as sodium sulfite, to chemically destroy dissolved oxygen. If all the oxygen is depleted, corrosion cannot occur. In the past, this approach has always worked well since boilers maintain system pressure continuously.

Today, however, boilers are not operated in the same way. Energy concerns have forced operations to cycle boilers “on/off”; this style of operation allows massive amounts of dissolved oxygen to enter the boilers. These high levels of dissolved oxygen can quickly deplete any residual sulfite, leaving the boiler vulnerable to oxygen attack.

SuperHot™ Complete, in addition to providing effective scale control, utilizes a unique high-temperature, non-consumable film-forming corrosion inhibitor system. This system provides excellent protection against corrosion, regardless of the level of oxygen entering the boiler. As a matter of fact, the inhibitor system actually works with dissolved oxygen to promote corrosion protection.

SuperHot Complete is much easier to control and maintain than the conventional sulfite-based scale and corrosion inhibitors. SuperHot Complete will also protect the boiler during the late fall and early spring when low loads cause the boilers to be off-line for long periods of time.

SuperHot Complete is a complete boiler protection system and includes corrosion control, scale control, and steam line protection.

Directions for Use

SuperHot™ Complete should be added to the feed water tank or condensate receiver directly from the shipping container. No product dilution or mixing is required. Feed SuperHot Complete to the feed water at a rate of 2 - 2.5 gallons per 1000 gallons of blowdown water. Maintain Sodium Molybdate at 80 - 160 ppm and condensate pH levels at > 8.0. Perform bottom blowdown at specified periods to remove solids accumulation. System TDS levels are determined by the quality of the fresh water makeup available. Generally TDS levels should be maintained below 3000 ppm. Your State Chemical Solutions representative will review the water conditions for the boiler systems and recommend a TDS limit for your system. Total concentration of antiscalent should not exceed 1.5 ppm (150 ppm
product) in the boiler feed water. Total concentration of diethylethanolamine should not exceed 15 ppm in boiler steam.